You have the questions
we have the answers
The answers to the most frequently asked questions about our sanitary products can be found here. Should you
want to know more, we are at your disposal personally.
The XT 3001 is certified for use in food processing areas by HACCP International and is one of the few hands-in hand dryers on the market to receive "Food Zone Classification SSZ" (Splash or Spill Zone) hygiene approval.
No. Only when the filter is inserted is a contact switched to the motor and the unit starts.
According to EU Regulation No. 852/2004 concerning food hygiene, the establishment of a HACCP (Hazard Analysis Critical Control Point) concept is mandatory for anyone who handles food or places it on the market. HACCP is a risk analysis based on the definition of critical points in the entire manufacturing and distribution process. It serves the purpose of checking whether there are still unacceptably high residual health risks for the consumer when handling the food.
The mesh filter protects the HEPA filter from coarse contaminants, e.g. lint, and can be cleaned with water when removed.
TT 1800 / T 500:
No runtime change possible
TT 1800 E / T 500 E:
Adjustment of switching distance continuously possible via adjusting potentiometer on the electronic plate
T 60 E:
Adjustment of switching distance infinitely variable via potentiometer on the electronic plate possible
T 80:
Adjustment of running time steplessly possible (approx. 30 - 60 sec.)
T 80 E:
Adjustment of switching distance infinitely variable via setting potentiometer on the electronic plate possible
ST 2400:
Adjustment of running time infinitely variable possible (approx. 30 - 120 sec.)
ST 2400 E:
Adjustment of switching distance not possible
No runtime change possible
TT 1800 E / T 500 E:
Adjustment of switching distance continuously possible via adjusting potentiometer on the electronic plate
T 60 E:
Adjustment of switching distance infinitely variable via potentiometer on the electronic plate possible
T 80:
Adjustment of running time steplessly possible (approx. 30 - 60 sec.)
T 80 E:
Adjustment of switching distance infinitely variable via setting potentiometer on the electronic plate possible
ST 2400:
Adjustment of running time infinitely variable possible (approx. 30 - 120 sec.)
ST 2400 E:
Adjustment of switching distance not possible
The filter has class H13 and removes 99.95% of bacteria from the air.
See planning aid Program overview sanitary.
TT 1800 - Series + T 500 - Series: a) Designed as standard with pre-mounted connection cable with plug and mounting plate. b) via fixed connection
T 60 - Series: a) Designed for fixed connection b) Also possible with connection cable (not included in scope of delivery)
T 80 - Series: a) Designed for fixed connection b) Also possible with connection cable (not included in scope of delivery) ST 2400 - Series: a) Fixed connection b) Also possible with mains connection cable (included in scope of delivery)
ST 2400 - Series: XT 3001 a) Fixed connection b) Also possible with connection cable (not included in scope of delivery)
TT 1800 - Series + T 500 - Series: a) Designed as standard with pre-mounted connection cable with plug and mounting plate. b) via fixed connection
T 60 - Series: a) Designed for fixed connection b) Also possible with connection cable (not included in scope of delivery)
T 80 - Series: a) Designed for fixed connection b) Also possible with connection cable (not included in scope of delivery) ST 2400 - Series: a) Fixed connection b) Also possible with mains connection cable (included in scope of delivery)
ST 2400 - Series: XT 3001 a) Fixed connection b) Also possible with connection cable (not included in scope of delivery)
The capacity is approx. 0.4 l. When the tank is full, the water tank symbol in the display flashes red until the water is emptied and the bowl is replaced. Empty the drip tray daily before the display lights up, as this prevents bacteria from accumulating and unpleasant odors from developing.
Renew the ZeroSmell tabs every 3 months. The tabs can be purchased as accessories under article no. 428857 (á 4 pcs.).
This depends on the operating and ambient conditions. The filter should be replaced after 6 months at the latest - washing it out with water is not permitted. After approx. 25,000 uses, the symbol for filter replacement also flashes red in the display. The filter can be purchased as an accessory under article no. 597331 (2 pcs. each).
For hygienic reasons, the water drain should be cleaned thoroughly on a regular basis using the brush included in the scope of delivery.
TTH 1800 / TH 500:
Running time possible via setting potentiometer on the electronic board in minute intervals from 1 - 9 minutes
TTH 1800 E / TH 500 E:
Adjustment of switching distance infinitely variable via setting potentiometer on the electronic board possible
TH 80 Z:
Adjustment of running time steplessly possible (approx. 30 - 480 sec.)
STH 2400 Z:
Adjustment of running time infinitely variable possible (approx. 60 - 240 sec.)
Running time possible via setting potentiometer on the electronic board in minute intervals from 1 - 9 minutes
TTH 1800 E / TH 500 E:
Adjustment of switching distance infinitely variable via setting potentiometer on the electronic board possible
TH 80 Z:
Adjustment of running time steplessly possible (approx. 30 - 480 sec.)
STH 2400 Z:
Adjustment of running time infinitely variable possible (approx. 60 - 240 sec.)
TTH 1800 - Series + TH 500 - Series
a) standard equipped with pre-assembled connection cable with contour plug
b) via fixed connection
TB 60 - Series:
a) designed for fixed connection through a mounting plate
b) also possible with connection cable
TH / TB 80 - Series:
a) Designed for fixed connection
b) Also possible with connection cable
STH 2400 - Series:
a) Fixed connection
b) Also possible with mains connection cable (included in delivery)
a) standard equipped with pre-assembled connection cable with contour plug
b) via fixed connection
TB 60 - Series:
a) designed for fixed connection through a mounting plate
b) also possible with connection cable
TH / TB 80 - Series:
a) Designed for fixed connection
b) Also possible with connection cable
STH 2400 - Series:
a) Fixed connection
b) Also possible with mains connection cable (included in delivery)
We could not clarify your question?
No problem, just write us a message and we will answer your question personally.